MODULE 11A · Syllabus 11.8 (ATA 26)

Chapter 11: Fire Protection

How fires and smoke are detected and put out on a transport aircraft: fire zones, continuous-loop, pneumatic, thermal-switch and smoke detectors, dual-loop logic, fixed Halon systems for engines, APU and cargo holds, the fire handle, discharge indicators, portable extinguishers and system tests.

11
Explainer slides
~35
Minutes reading
23
Flashcards
23
Quiz questions
Home › Courses › Module 11A › Chapter 11
🎬 Explainer video

Watch the 11-slide walkthrough

Narrated by your browser's text-to-speech voice — pick a voice and speed in the player bar. Press space to play/pause, arrow keys to change slide. No sound? It still plays with captions.

Read the full transcript
🎯 What you'll learn
  • The fire triangle, fire classes and designated fire zones
  • Fire and overheat detection: continuous-loop (resistance and pneumatic), thermal switches and thermocouples
  • Dual-loop AND logic, fault reversion and the fire warning
  • Smoke detection in cargo holds, lavatories and avionics bays
  • Fixed extinguishing systems: Halon 1301 bottles, squibs, two-shot systems, cargo high-rate and metered discharge
  • What the engine fire handle does; red and yellow discharge indicators
  • Portable fire extinguishers: agents, uses and checks
  • System tests and the maintenance of detectors and bottles
📖 The lesson

Fire basics and fire zones

Fire triangle (+ chain reaction) HEAT FUEL OXYGEN chemical chain reaction Remove any side and the fire goes out Classes and agents A Ordinary combustibles: paper, fabric, wood water, Halon B Flammable liquids: fuel, oil, hydraulic fluid Halon, CO₂, dry powder C Electrical equipment (FAA usage)* Halon, CO₂ — never water D Burning metals: magnesium, titanium dry powder (special) * In Europe class C means flammable gases
Fire basics. A fire needs fuel, heat and oxygen, sustained by a chemical chain reaction. Water and CO₂ cool and smother; Halon works mainly by breaking the chain reaction, which is why so little of it is needed. The agent must suit the class of fire — never water on electrical or burning-liquid fires.

Aircraft carry three kinds of fire protection: detection (so the crew knows), fixed extinguishing systems in the places nobody can reach in flight, and portable extinguishers in the cabin and flight deck. CS-25 defines designated fire zones — the engine power and accessory sections, the APU compartment and combustion heaters — which must have fire detection, fixed extinguishing, fireproof firewalls (Chapter 5) and drainage. Other areas get what their risk demands: smoke detection in cargo holds, lavatories and avionics bays, overheat detection along bleed-air ducts and in wheel wells, and built-in extinguishers in cargo holds and lavatory waste bins.

Fire and overheat detection

Continuous-loop detectors

Resistance / capacitance element Inconel outer tube eutectic salt / thermistor centre wire Heat lowers the core's resistance (or changes capacitance) → current flows → alarm. Resets on cooling Pneumatic (gas) element sealed tube filled with helium hydride core releases hydrogen in a local fire Responder alarm + integrity Average overheat: gas expands → alarm switch closes Local fire: hydride gives off gas → pressure jumps Tube leak: integrity switch opens → FAULT
Two kinds of continuous-loop sensor. In the electrical type, a core of eutectic salt or thermistor material between a centre wire and the outer tube conducts when heated anywhere along its length. In the pneumatic type, a sealed gas-filled tube responds both to general overheat (gas expansion) and to a local fire (gas released from a hydride core).
  • Resistance (eutectic salt) type — an Inconel tube with a centre wire embedded in a eutectic salt or ceramic. When any part of the element is heated, its resistance falls and current flows between wire and tube, signalling fire. It cools and resets after the fire.
  • Thermistor / capacitance types — similar elements in which the core's resistance or capacitance changes with temperature, allowing the control unit to distinguish an average overheat from a local fire.
  • Pneumatic (gas) type — a sealed tube filled with helium and a hydride core. A general rise in temperature makes the gas expand and closes an alarm switch (overheat); a local fire makes the core release hydrogen, raising the pressure sharply (fire). A separate integrity switch, held closed by the normal gas pressure, opens and signals a fault if the tube is cut or leaks.

Other detectors

  • Thermal switches (spot detectors) — bimetallic switches that close at a set temperature, wired in parallel so any one gives the warning.
  • Thermocouple (rate-of-rise) systems — exposed active junctions and protected reference junctions; a rapid temperature rise creates a voltage difference that triggers the alarm, while a slow rise (normal warm-up) does not.
  • Optical flame detectors — infrared or ultraviolet sensors on some installations.
Engine fire zone loop A loop B Detection control unit AND logic · fault monitoring FIRE warning bell · red handle light · master warning Both loops must sense fire (AND); if one loop fails, the unit reverts to the healthy loop alone
Dual-loop detection. Two independent sensing loops run side by side through each fire zone. The control unit gives a fire warning only when both loops detect (AND logic), which avoids false alarms from one damaged loop; a faulty loop is flagged and the system continues on the other.
Dual-loop logic

Two loops (A and B) follow the same route. A fire warning needs both to detect (AND logic), so a single chafed or wet loop cannot give a false warning. If a loop fails, the control unit reports a fault and switches to single-loop operation on the other. The warning is a fire bell, the red light in the fire handle and the master warning.

Smoke detection

  • Photoelectric (light-scattering) detectors — air is drawn or flows through a chamber; smoke particles scatter a light beam onto a photocell. The most common type in cargo holds, lavatories and avionics bays.
  • Ionisation detectors — a small radioactive source ionises the air in a chamber; smoke reduces the ion current.
  • Cargo-hold systems use several detectors (often in pairs with AND logic, as for loops) and must detect a fire within one minute (CS 25.858). A warning shuts off the hold's ventilation and prompts the crew to discharge the cargo extinguisher.
  • Light aircraft may have carbon-monoxide detectors (Chapter 6).

Fixed fire-extinguishing systems

The agent in fixed systems is still mainly Halon 1301 (bromotrifluoromethane): effective in small concentrations, non-corrosive, leaves no residue and has low toxicity. Its production has stopped because it damages the ozone layer, so stocks are recycled and replacement agents are being introduced, first for portable and lavatory extinguishers.

Bottle 1 Halon 1301 + N₂ Bottle 2 Halon 1301 + N₂ squib-fired discharge heads to engine 1 to engine 2 two-way check valves let either bottle feed either engine (two shots) pressure switch / gauge RED disc: thermal (overheat) discharge YELLOW disc: normal discharge by the crew Pulling the fire handle: closes the fuel shut-off valve closes the hydraulic shut-off valve closes the bleed-air valves trips the generator (field off) silences the bell, arms the squibs Turning / pushing it then fires bottle 1 — and if the fire persists, bottle 2 (second shot)
A two-shot engine fire-extinguishing system. Each spherical bottle holds Halon 1301 pressurised with nitrogen and has explosive-cartridge (squib) discharge heads. Check valves let either bottle discharge into either engine. A red disc on the skin shows a thermal overpressure discharge; a yellow disc shows a normal discharge.
  • Bottles (containers) — usually spherical, stainless steel or titanium, holding liquid Halon pressurised with nitrogen. Each has a pressure gauge and/or pressure switch (pressure varies with temperature, so readings are checked against a chart) and a temperature/pressure-sensitive safety relief diaphragm.
  • Discharge heads — fired by an explosive cartridge (squib) that ruptures a frangible disc; high-rate-discharge bottles empty in about 1–2 seconds. Cartridges have a limited life and are tracked.
  • Two-shot systems — two bottles connected through two-way check valves so either can be discharged into either engine: if the fire is still burning after the first shot (typically 30 seconds later), the second bottle is fired.
  • Discharge indicators — a red disc on the fuselage skin is blown out if a bottle has discharged overboard through its relief because of overheating; a yellow disc is blown out by a normal discharge commanded by the crew. A missing disc must be investigated on the walk-round.
  • APU — one bottle; on the ground many APUs shut down and discharge automatically on fire, sound an external horn, and can be controlled from an external panel (often in the main-gear well).
  • Cargo holds (Class C) — a high-rate discharge knocks the fire down, then a metered (low-rate) discharge maintains the Halon concentration for the rest of the flight to the nearest suitable airport (one hour or more on extended-range aircraft). Ventilation to the hold is shut off and the liners keep the agent in (Chapter 10).
  • Lavatory waste bins — a small automatic extinguisher with heat-sensitive (fusible) nozzles that discharge into the bin when they melt.

The engine fire handle

Pulling (or unlocking) the engine fire handle or switch isolates the engine: it closes the low-pressure fuel shut-off (spar) valve, the hydraulic shut-off valve and the bleed-air valves, trips the generator, silences the bell and arms the squibs. Turning or pushing it then fires the selected bottle. Fire handles are lit red by a fire warning and can be tested from the flight deck.

Portable fire extinguishers

AgentUse on aircraftNotes
Halon 1211 (and approved replacements)Flight deck and cabin — classes A, B and CVaporising liquid; interrupts the chain reaction; no residue; check by weight and pressure gauge
Water (often with antifreeze)Cabin — class A fires (paper, fabric, seats)Never on electrical or fuel fires
Carbon dioxide (CO₂)Older flight-deck and ground useChecked by weight; can cause cold burns and displace oxygen in confined spaces
Dry powderGround equipment, wheel and metal firesNot used in cabins: powder obscures vision and is corrosive to equipment

Checks: correct type in each marked location, secure in its bracket, safety pin and tamper seal intact, gauge in the green, weight within limits, inspection label and test dates current (periodic hydrostatic test of the cylinder). Discharged or doubtful extinguishers are replaced.

System tests and maintenance

  • Fire/overheat detection test — the flight-deck test switch checks loop continuity and the warning circuits (bell, lights, master warning) for each zone; a fault test checks the fault-monitoring logic.
  • Squib (cartridge) circuit test — a low-current continuity test of the discharge circuits, shown by lights; it cannot fire the cartridge.
  • Detector elements — inspect for kinks, dents, chafing, crushed sections and loose clamps; keep the minimum bend radius and the grommets in their clamps; damaged elements are replaced, never repaired by straightening.
  • Bottles — pressure checked against the temperature/pressure chart, weight checks, cartridge life and expiry, discharge-indicator discs in place; after a discharge the bottle is replaced and the lines cleared as the AMM requires.
  • Safety — squibs are explosive devices: short-circuit caps, isolated circuits and correct handling are mandatory; Halon and CO₂ displace oxygen, so ventilate after any discharge in an enclosed area.
🧠 Mind map

See the whole chapter at a glance

🃏 Flashcards

Test your recall — tap a card to flip it

✅ Chapter quiz

23 exam-style questions

📚 Further reading

Free official references

Chapter progress

Next chapter →