MODULE 4 · Syllabus 4.3 (a) · level 1

Chapter 8: Servomechanisms: Principles and Sensors

Open- and closed-loop control, what makes a servomechanism, and the words examiners love — feedback, follow-up, error, null, overshoot, damping, deadband and hunting — plus the sensors that close the loop: analogue transducers (potentiometers, LVDTs, RVDTs), proximity switches, digital tachometers and encoders.

8
Explainer slides
~35
Minutes reading
25
Flashcards
26
Quiz questions
Home › Courses › Module 4 › Chapter 8
🎬 Explainer video

Watch the 8-slide walkthrough

Narrated by your browser's text-to-speech voice — pick a voice and speed in the player bar. Press space to play/pause, arrow keys to change slide. No sound? It still plays with captions.

Read the full transcript
🎯 What you'll learn
  • Open-loop and closed-loop systems; what a servomechanism is
  • Feedback, follow-up, error signal and null
  • Response: overshoot, damping (under, critical, over), deadband and hunting
  • Analogue transducers: potentiometers, LVDTs, RVDTs, tachogenerators, strain gauges
  • Proximity switches — contactless position sensing for gear, doors and flaps
  • Digital tachometers and encoders (incremental, absolute, Gray code)
  • B2 extension: the PID controller
📖 The lesson

Open-loop and closed-loop systems

  • An open-loop system acts on its input but never checks the result. A trim actuator that runs only while a switch is held, a heater on a timer, a stepper motor driven without position feedback — none of these knows whether the output is right, so loads, friction, wear and disturbances go uncorrected. Open-loop systems are simple, cheap and stable.
  • A closed-loop system measures its output with a sensor and feeds that measurement back to be compared with the input. Any difference — the error — drives a correction, so the system corrects itself. Autopilot servos, cabin temperature and pressure controllers, flap and slat position control, generator voltage regulation and FADEC fuel metering are all closed loops.
Open loop — no feedback command switch / input controller amplifier actuator motor output e.g. trim position nothing measures the result — disturbances and errors go uncorrected Closed loop (servomechanism) — the output is measured and fed back demand + − error servo amplifier power gain servo motor or actuator load / output e.g. control surface feedback transducer synchro · LVDT · potentiometer feedback (follow-up)
Open and closed loops. An open-loop system acts on its command without ever checking the result. A closed-loop system measures its output, feeds it back and compares it with the demand. The difference — the error signal — is amplified to drive the motor until the error is zero (null). A closed loop that controls a mechanical position with power amplification is a servomechanism.

The servomechanism and its vocabulary

A servomechanism is a closed-loop control system whose output is a mechanical position (or its rate), and in which a small, low-power command controls a large output through power amplification. Its parts:

  • Input (demand, command) — for example a pilot's control input, an autopilot computer command or a selector position.
  • Error detector (comparator) — subtracts the feedback from the demand. Error signal = demand − actual position.
  • Servo amplifier — raises the error signal's power.
  • Servo motor or actuator — an electric motor, or a hydraulic actuator through a servo valve, that moves the load.
  • Feedback (follow-up) transducer — measures the actual output: a synchro, potentiometer, LVDT/RVDT or encoder.
TermMeaning
FeedbackA signal proportional to the output, returned to the input to be compared. Negative feedback opposes the error, which makes the loop self-correcting.
Follow-upThe output following the input. Also the feedback element itself (a "follow-up" synchro or potentiometer), which cancels the error as the output reaches the demanded position.
NullThe condition of zero error: output equals input, and the motor stops.
OvershootThe output's inertia carries it past the demanded position before it comes back.
DampingAnything that opposes motion in proportion to its speed — friction, viscous dampers, or electrical velocity (rate) feedback from a tachogenerator — and so reduces overshoot and oscillation.
DeadbandA small band of error either side of the null in which the system does not respond. It stops the servo chasing tiny errors and jittering, but too wide a band reduces accuracy.
HuntingContinuous oscillation of the output back and forth through the null. Causes: too much gain, too little damping, too small a deadband, or backlash in the gears.
Response to a step demandtimepositiondemandovershootunder-damped: overshoots and oscillatescritically damped: fastest, no overshootover-damped: sluggishHunting and deadbandhunting: endless oscillation about the null(too much gain, too little damping, backlash)nulldeadband: small errors inside the band get no correctiontoo narrow → hunting · too wide → poor accuracy
How a servo responds. Inertia carries the output past the demand — overshoot — unless damping absorbs it. Too little damping and the output oscillates before settling; critical damping reaches the demand fastest without overshoot; too much is sluggish. Continuous oscillation about the null is hunting. A small deadband around the null stops the servo chasing tiny errors.
  • Under-damped: fast, but overshoots and oscillates before settling. If damping is far too low it may hunt continuously.
  • Critically damped: reaches the demand in the shortest time without overshoot — the design aim, often set slightly under-damped for speed.
  • Over-damped: no overshoot but sluggish.
  • When the input keeps moving, the output follows with a small lag (velocity error).

Analogue transducers

A transducer converts one form of energy into another — here, a physical quantity into an electrical signal. An analogue transducer gives a signal that varies continuously with the quantity.

Potentiometer +V Vout wiper Vout ∝ wiper position simple, but the contact wears LVDT — linear variable differential transformer S1 P S2 soft-iron core to moving part primary fed with AC · secondaries wound in series opposition no contact, no wear, very fine resolution null (core centred) phase 180° phase 0° |Vout| core position Others RVDT rotary LVDT — limited angle tachogenerator speed → voltage strain gauge force → resistance synchro / resolver angle → AC voltages (Ch 9) thermocouple temperature → mV
Analogue transducers. They turn a position (or speed, force, temperature) into a continuously variable electrical signal. A potentiometer is simple but its wiper wears. An LVDT has an AC-fed primary and two secondaries connected in opposition around a moving core. Its output is zero at the centre (null), grows with displacement, and its phase shows which way the core has moved.
  • Potentiometer — a resistance track with a moving wiper. The output voltage is proportional to position. It is simple and works on DC, but the sliding contact wears, gets noisy and has finite resolution.
  • LVDT (linear variable differential transformer) — a primary coil excited by AC, two secondary coils connected in series opposition, and a soft-iron core attached to the moving part. With the core centred, the two secondary voltages cancel: the null. Moving the core increases one and decreases the other, so the output amplitude shows how far it has moved and the phase (0° or 180° relative to the excitation) shows which way. With no contact it does not wear and has effectively infinite resolution, which is why LVDTs sit inside flight-control actuators, servo valves and engine fuel-metering units.
  • RVDT — the rotary version, for limited angles (typically up to about ±40–60°). It is used on control columns, pedals and side-sticks.
  • Tachogenerator — a small generator whose output voltage (or frequency) is proportional to speed. It provides speed measurement and the rate feedback that damps servos.
  • Others include strain gauges (force and pressure via a bridge), thermocouples and resistance thermometers (temperature), capacitance probes (fuel quantity) and synchros and resolvers (angle — Chapter 9).

Proximity switches

Many aircraft use proximity sensors instead of mechanical microswitches to report the positions of the landing gear, gear doors, passenger and cargo doors, thrust reversers and flaps. Each sensor is a sealed coil, and its target is a steel plate on the moving part. When the target comes within range, the coil's inductance changes, and an electronics unit — a proximity switch electronics unit (PSEU) or landing gear control and interface unit — decides "target near" or "target far". It also monitors each sensor for open or short circuits.

Inductive proximity sensor sensor (coil) to PSEU steel target gap moves with gear / door target near → inductance changes → 'NEAR' target far → 'FAR' · open or short circuit → sensor FAULT no moving parts or contacts · sealed · set the gap to the AMM figure Proximity switch electronics unit gear down & locked gear doors closed cargo door locked reverser stowed PSEU / LGCIU near/far + BITE to warnings, indications, air/ground logic
Proximity switches. A sealed coil senses when a steel target comes close: the target changes the coil's inductance, and an electronics unit (a PSEU or landing gear control and interface unit) decides near or far and also flags a broken or shorted sensor. With no contacts or moving parts they outlast microswitches; the critical maintenance item is the gap between sensor and target.
  • Advantages: no moving parts or electrical contacts to wear, bounce or corrode; sealed against water, ice and de-icing fluid; built-in fault monitoring.
  • Maintenance: the gap between sensor and target must be set to the AMM figure, usually with a feeler gauge. Damaged targets, loose brackets, debris and wiring faults are the usual causes of "sensor disagree" faults. The system's BITE pages show each sensor's near/far state.

Digital tachometers and encoders

  • Speed sensors produce a pulse each time a tooth of a toothed wheel (a phonic wheel) passes. A variable-reluctance (magnetic) pickup has a permanent magnet and a coil; a Hall-effect sensor also works down to zero speed. The pulse frequency is proportional to speed. Examples are engine N1/N2 speed probes and the wheel-speed transducers of anti-skid systems.
  • A digital tachometer counts those pulses over a fixed time, or measures the time between them, and computes RPM — no analogue meter movement involved.
  • An incremental encoder uses a slotted (optical) or magnetised disc to produce pulses as it turns. Counting pulses gives the change in position; the pulse rate gives speed. Two tracks A and B, 90° apart (quadrature), give the direction — whichever leads. An index pulse marks one point per revolution. After a power loss the count is lost, so the system must re-home.
  • An absolute encoder reads a unique digital code for every position, so it knows its position immediately at power-up. The code is usually Gray code, in which only one bit changes between adjacent positions. A reading taken on a boundary can then never be badly wrong. In plain binary, 011 to 100 changes three bits at once, and misaligned sensors could briefly read anything. Aircraft altitude encoders (the Gillham code for Mode C transponders) and many position sensors use Gray-type codes.
Incremental encoder LED sensors A, B A B A and B are 90° apart: which leads gives the direction pulse count = how far · rate = speed position is lost when power is lost Absolute encoder — 3-bit Gray code 0 1 2 3 4 5 6 7 each position has its own code pos binary Gray 0 000 000 1 001 001 2 010 011 3 011 010 4 100 110 5 101 111 6 110 101 7 111 100 Gray: only ONE bit changes per step
Encoders. An incremental encoder's slotted disc chops a light beam into pulses: counting them gives position, their rate gives speed, and two tracks 90° apart (A and B) give the direction. An absolute encoder reads a unique code for every position, so it knows where it is at power-up. Gray code is used because only one bit changes between neighbouring positions, so a reading taken on a boundary is never badly wrong.

B2 extension: the PID controller

Most modern servo and process loops are PID controllers. The proportional term drives the output in proportion to the error. The integral term adds up the error over time, so even a small steady error is eventually removed (no steady-state error). The derivative term responds to the rate of change of the error, anticipating and damping overshoot. Tuning the three gains trades speed against overshoot and hunting.

🧠 Mind map

See the whole chapter at a glance

🃏 Flashcards

Test your recall — tap a card to flip it

✅ Chapter quiz

26 exam-style questions

📚 Further reading

Free references

Chapter progress

Next chapter →